Electromagnetic Effects · Cambridge syllabus 4.5 · Lesson 6 of 6
Transformers
Includes Supplement objectivesAn alternating primary current produces changing magnetic flux in an iron core and induces a secondary EMF. For an ideal transformer, Vs/Vp = Ns/Np and input power equals output power. Higher transmission voltage reduces current for fixed power, reducing I²R losses.
By the end, you can
- Primary coil.
- Secondary coil.
- Iron core.
- Explain voltage changes.
- Use the transformer relationship.
- Explain why high voltage is used for transmission, and state its advantages, including smaller energy losses in the cables.
- Explain why a higher transmission voltage means a smaller current, and so smaller losses in the cables. [Supplement]
- Explain the principle of operation of a simple iron-cored transformer. [Supplement]
- Recall and use IpVp = IsVs for a transformer that is 100% efficient. [Supplement]
- Recall and use P = I²R to explain why power losses in cables are smaller when the voltage is greater. [Supplement]
Transformer construction
A transformer is two coils of insulated wire wound on the same soft iron core: a primary coil, connected to the supply, and a secondary coil, connected to the load. The coils are not joined electrically; no current flows from one to the other, and the link between them is entirely magnetic.
The core is soft iron because soft iron is easily magnetised and loses its magnetism just as easily, so it can follow a field that keeps changing. The wire is insulated so that the current goes round each turn of the coil rather than straight across from turn to turn or into the core.
A transformer works only with an alternating supply. Connected to a battery it gives no output from the secondary at all, except for a brief pulse at the moment of switching on or off.
Worth remembering
- Two coils of insulated wire, primary and secondary, on a shared soft iron core.
- The coils are linked magnetically, not electrically.
- A transformer works only with alternating current.
Step-up and step-down transformers
The voltages are in the same ratio as the numbers of turns: Vₚ ÷ Vₛ = Nₚ ÷ Nₛ. A step-up transformer has more turns on the secondary than the primary and increases the voltage; a step-down transformer has fewer and reduces it.
A transformer with 100 turns on the primary and 500 on the secondary, supplied at 20 V, gives 20 × 500 ÷ 100 = 100 V: five times the turns, five times the voltage.
Working the other way, a transformer with 2000 turns on its primary is used to step 230 V down to 11.5 V. The number of secondary turns is Nₛ = Nₚ × Vₛ ÷ Vₚ = 2000 × 11.5 ÷ 230 = 100 turns. The commonest mistake is to turn the ratio upside down, so always check: the coil with more turns has the larger voltage.
- Vₚ ÷ Vₛ = Nₚ ÷ Nₛ
- The voltages are in the same ratio as the numbers of turns.p primary, s secondary. V in volts, N a number of turns.
Worth remembering
- Vₚ ÷ Vₛ = Nₚ ÷ Nₛ.
- Step-up: more turns on the secondary, larger output voltage. Step-down: fewer turns, smaller output.
- Check the answer: the coil with more turns has the larger voltage.
National Grid
Electricity reaches homes from distant power stations through the National Grid, a network of cables carried on pylons or run underground. The generators produce electricity at about 25 kV. Step-up transformers at the power station raise this to a very high voltage, such as 400 kV, for the long journey along the transmission cables, and step-down transformers near towns lower it in stages to 230 V for use in homes.
Transmitting at a high voltage has two big advantages. Much less energy is wasted heating the cables, so more of it reaches the users; and the cables can be thinner, which makes them lighter and cheaper and lets the pylons be lighter too. Transformers work only with alternating current, which is a main reason why the mains supply is a.c.
The reason lies in the current. The power delivered is P = IV, so for the same power, raising the voltage lowers the current in the same proportion: ten times the voltage means a tenth of the current. A smaller current heats the cables far less, so much less power is lost on the way.
Worth remembering
- Step-up transformers raise the voltage for transmission; step-down transformers lower it for use.
- High-voltage transmission wastes less energy and allows thinner, cheaper cables.
- For the same power, a higher voltage means a smaller current, so less heating in the cables.
How a transformer works
An alternating current in the primary coil produces a magnetic field in the soft iron core, and because the current keeps changing in size and direction, so does the field: it grows, shrinks and reverses many times a second. The core carries this changing field through the secondary coil, and a changing magnetic field through a coil induces an e.m.f. in it. So the secondary produces an alternating e.m.f. with the same frequency as the supply. A direct current would make a steady field, which induces nothing.
A transformer cannot create energy. If it is 100% efficient, the power delivered by the secondary equals the power taken by the primary, and since power = current × voltage, IₚVₚ = IₛVₛ. A transformer stepping 12 V up to 60 V, five times the voltage, delivers a secondary current five times smaller than the primary current: a primary current of 2.0 A gives 12 × 2.0 ÷ 60 = 0.40 A. Real transformers are slightly less than 100% efficient, because a little energy heats the coils and the core.
This is why high-voltage transmission saves energy. The power wasted heating a cable of resistance R carrying a current I is P = I²R. Suppose a power station sends 5.0 MW along cables with a total resistance of 4.0 Ω. At 50 kV the current is I = P ÷ V = 5 000 000 ÷ 50 000 = 100 A, and the power lost is 100² × 4.0 = 40 000 W, or 40 kW. At 500 kV, ten times higher, the current is 10 A and the loss is 10² × 4.0 = 400 W. Ten times the voltage gives a tenth of the current, and because the current is squared, a hundredth of the loss.
- IₚVₚ = IₛVₛ
- For a 100% efficient transformer, the power out equals the power in.p primary, s secondary. Raising the voltage lowers the current by the same factor.
- P = I²R
- The power wasted heating a cable rises with the square of the current.P in W, I in A, R in Ω.
Worth remembering
- A changing current in the primary makes a changing field in the core, inducing an e.m.f. in the secondary.
- For 100% efficiency, IₚVₚ = IₛVₛ: step the voltage up and the current goes down.
- Cable loss is P = I²R, so ten times the voltage gives a hundredth of the power loss.
Worked example
A 100-turn primary and 500-turn secondary ideally step 12 V up to 60 V.
Transform voltage and current
Part of the full Physics course. This unit’s free simulation is Build a circuit.
Practice
Warm-up · not marked
Check your understanding
Answer in your own words, then compare with the worked answer. Nothing here is saved or scored.
Worked answer
Ns = 1000 × 12/240 = 50 turns.
Check your method, units and explanation against it.
Marked practice
Set 1 of 5 · easiest first · Checked as you go, with the worked answer. Sign in or create a free account to save your progress.